Datum Systems, Inc. PSM-500 Modem Remote Control Protocol
Rev 0.93 12/12/10
Unit Alarm, Command [08h]
Read Change Flags
Unit Alarm, Read Flags
Unit Alarm, Write Enable Flags
Unit Alarm, Write Flags
[RefAlm3-RefAlm0] = Reference Alarm Mode, 4b, 0=None, 1=Alarm A, 2=Alarm B, 3=Alarm A&B,
4=Mute CXR, 5=Mute CXR & Alarm A, 6=Mute CXR & Alarm B, 7=Mute CXR & Alarm A&B, 8=Mute
BUC & CXR, 9=Mute BUC/CXR & Alarm A, 10=Mute BUC/CXR & Alarm B, 11=Mute BUC/CXR &
Alarm A&B
[OcxAlm3-OcxAlm0] = OCXO Alarm Mode, 4b, 0=None, 1=Alarm A, 2=Alarm B, 3=Alarm A&B,
4=Mute CXR, 5=Mute CXR & Alarm A, 6=Mute CXR & Alarm B, 7=Mute CXR & Alarm A&B, 8=Mute
BUC & CXR, 9=Mute BUC/CXR & Alarm A, 10=Mute BUC/CXR & Alarm B, 11=Mute BUC/CXR &
Alarm A&B
[TstAlm1-TstAlm0] = Test Active Alarm Mode, 2b, 0=None, 1=Alarm A, 2=Alarm B, 3=Alarm A&B
[HrdAlm1-HrdAlm0] = Hardware Alarm Mode, 2b, 0=Mute CXR, 1= Mute CXR & Alarm A, 2= Mute
CXR & Alarm B, 3= Mute CXR & Alarm A&B
[Beep1-Beep0] = Beeper Alarm Mode, 2b, 0=None, 1=On Alarm A, 2=On Alarm B, 3=On Alarm A&B
Komentáře k této Příručce