Datum Systems, Inc. PSM-500 Modem Remote Control Protocol
Rev 0.93 12/12/10
Mod BUC, Command [46h]
Read Change Flags (L-Band Only)
Mod BUC, Read Flags
Mod BUC, Read Bytes
BUC Voltage Out, Signed 16b, (0 to >600), 100mV Increments
BUC Voltage Min, Signed 16b, (80 to 600), 100mV Increments
BUC Current Out, Signed 16b, (0 to >600), 10mA Increments
BUC Current Max, Signed 16b, (5 to 600), 10mA Increments
BUC Current Min, Signed 16b, (5 to 600), 10mA Increments
BUC LO Frequency, Unsigned 48b, (0 to 50,000,000,000), 1Hz Increments
Mod BUC, Write Enable Flags
Mod BUC, Write Flags
Mod BUC, Write Bytes
BUC Voltage Min, Signed 16b, (80 to 600), 100mV Increments
BUC Current Max, Signed 16b, (5 to 600), 10mA Increments
BUC Current Min, Signed 16b, (5 to 600), 10mA Increments
BUC LO Frequency, Unsigned 48b, (0 to 50,000,000,000), 1Hz Increments. Note 1
[PwrEn2-PwrEn0] = BUC Power, 3b, 0=Disabled, 1=Enabled
[RefEn2-RefEn0] = BUC 10MHz Ref, 3b, 0=Disabled, 1=Enabled
Note 1: When the BUC LO frequency is not zero the Mod IF frequency is converted to an RF frequency.